6. Web Browser Operation

6.1.

Password Protection

iBoot uses two passwords, one for normal power control use and one that also
provides access to the setup functions. From the factory, both passwords are
the same. (PASS)

Open your browser and enter the IP address of iBoot into the address bar. If
your have changed the IP address by any of the methods described, enter that
address, otherwise, use the default IP address 192.168.1.254

Enter the default password PASS or your password if it has been changed. A
Username is not required. When the proper password is received the Control
and Status Page is displayed.

6.2.

Control and Status Page

Once the password is entered, the following page is
displayed. (Only one person can be connected to the iBoot
at a time.)

To control the power, click on the appropriate button.
During power cycling, the Power Status bar will indicate the
temporary status, with a blue background. Once the cycle
is complete, the status bar will revert to its original
condition. To abort a power cycle, click on either Power
On or Power Off buttons. iBoot will assume the status
selected.


If the Auto-Ping or Heartbeat Features are in use then the
page will also display the current status, OK or Triggered,
for each, with a counter of how many times that feature was triggered. If
connecting with the System Password, a reset button for the counter is provided.

Use the Refresh button to obtain the latest status of iBoot. Using your browser's
refresh button can lead to inadvertent power switching.

To access the Setup page, the System Password must be used for the initial
login. The factory default for the System Password, as well as the operation
password is PASS. Both passwords can be changed in Setup.

When you are finished with iBoot, click on Logout. A confirmation page will be displayed. If you close your browser
window without first clicking Logout, there will be a two minute delay before you can re-access iBoot.

iBoot uses an inactivity timer for security. When there is no activity for 2 minutes, the user is logged out and the
password will need to be entered again for access. This is to prevent accidental lockout by leaving the user logged
in.