beautypg.com

Heartbeat monitor, Power and system passwords – Dataprobe iBoot-Hub Operation Manual User Manual

Page 11

background image

140926E

iBoot-HUB

Page 11

Action: Select from

None

AutoPing not used

Power On

– Latch

Upon triggering, iBoot will power on and remain so until changed via the
web, ibootctl.exe or direct messaging.

Power On

– Follow

Upon triggering, iBoot will power on. When the ping response returns, iBoot
will power off.

Power Off

– Latch

Upon triggering, iBoot will power off and remain so until changed via the
web, ibootctl.exe or direct TCP/IP control.

Power Off

– Follow

Upon triggering, iBoot will power off. When the ping response returns, iBoot
will power on.

Power Cycle

Upon triggering, iBoot will cycle the power. iBoot will wait the Ping
Frequency x Fail Count; if the response does not return, the power will be
recycled again. This will continue until the ping response returns or Auto
Ping is turned off. Make sure your Auto Ping frequency is longer than the
time required to reboot your device.

Power Cycle Once

Upon triggering, iBoot will cycle power one time. It will not cycle again
automatically until the ping response returns and is lost again.


With Auto-Ping operational, the main iBoot page will display the current status of this feature. The status will be OK
to indicate that iBoot is receiving responses to the ping, or that the fail counter has not yet been exceeded.

If the fail count has been exceeded, the status will change to Triggered. The Trigger Counter indicates the number
of times the Auto-Ping feature has been triggered. A counter reset button is provided when logging in with the
System password.

7.4.

Heartbeat Monitor

See Advanced Operation for Heartbeat Monitor Setup

7.5.

Power and System Passwords

Two passwords are used by iBoot. The Power Password allows access to the control of iBoot, but not to the Setup
functions. When this password is used, the main screen will not have a link to Setup. The System Password allows
access to both the Main Screen and the Setup Screen. The default for both Passwords is PASS. Passwords can
be up to 10 characters long and are case sensitive.

Enter the current password then the new password twice to confirm. Click Apply for each password being changed.