beautypg.com

Dataprobe iBoot-Hub Operation Manual User Manual

Page 7

background image

140926E

iBoot-HUB

Page 7

4. Windows (98 and Later)

a. Open a DOS window. (Run: Command)
b. Type the following command:

arp -s

Where is the desired IP address (in dotted decimal) for the iBoot and the address> is the MAC Address of the iBoot. The MAC Address of the iBoot is located on bottom of
the unit.


Example: arp -s 63.211.86.165 00-50-c2-05-01-c1

|new IP addr| |---MAC addr----|

c. Ping the iBoot to program the IP address into the iBoot.

Type: ping


Note: If the ping command returns “host not responding” 4 times then the address has not been programmed
properly. The process must be run within two minutes of powering up the iBoot, and not have been set by a DHCP
server. Check the IP or MAC Address. Repeat step 2. If the problem persists, contact the Dataprobe Tech
Support.

d. Delete the entry from the ARP cache by typing: arp -d

e. Ping the iBoot to confirm that it has been programmed.

If the iBoot fails to respond, repeat steps 2-4 above. If the problem persists, contact the Dataprobe

support hotline.

f.

Unix, Linux, MAC and others

Consult your systems administrator for information on other means of setting an IP Address. The unit should be
pinged after the IP Address has been set to confirm proper operation.