Maintenance and Troubleshooting

4-17

Display is stuck on bright or dim.

Check Manual/Auto dimming in Venus 1500

software.

Check light detector cable.

Check the address on the Light Sensor

Check light detector for obstructions.

Replace the light detector.

Replace the controller.

4.10 Initial Operation Information

Every time the display is operated, the display will run through an initialization in
which it will display the following:

1. Product Name (Galaxy®)
2.
Display Size (Row x Column)
3.
Shading (32K RGB)
4.
Bootloader Version (OS X.XX)
5.
Firmware Number (ED-13305)
6.
Firmware Revision (Rev X.XX)
7.
Hardware Address (HW:XX)
8.
Software Address (SW:XX)
9.
IP Address: (172.16.192.25)
10.
Subnet Msk: (255.255.0.0)
11.
COM1 Configuration (C1:V15) ((Modem C1:V15) If a Modem is present)
12.
Line Frequency (CLK:60 Hz)
13.
Display Name Description