beautypg.com

Troubleshooting, Troubleshooting -16, 9 troubleshooting – Daktronics AF-3165-34-RGB User Manual

Page 58

background image

Maintenance and Troubleshooting

4-16

4.9 Troubleshooting

This sub-section contains some symptoms that may be encountered in the displays.
This list does not include every possible symptom, but does represent common
situations that may occur.

Symptom/Condition Possible

Cause/Remedy

One or more LEDs on a single

module fail to light.

Replace/check ribbon cables on the module.

Replace the module.

One or more LEDs on a single

module fail to turn off.

Replace/check ribbon cables on module.

Replace the module.

A section of the display is not

working. The section extends all

the way to the right side of the

display.

Replace/check the ribbon cable.

Check power to module.

Replace the first module/driver on the left side

of the first module that is not working.

Replace the second module that is not

working.

Replace the power supply assembly on the

first module that is not working.

One row of modules does not

work or is garbled.

Replace/check ribbon cable to first module.

Check for bent pins on module and controller

Replace first module.

Replace controller.

Check the fuses in the power termination box.

A group of modules, (a column of

block) which share the same

power supply assembly, fail to

work.

Check voltage to module.

Check the wire connections at the power

supply.

Replace the power supply assembly.

Entire display fails to work.

Check for proper line voltage into the power

termination panel.

Check fuse in power termination panel.

Check for correct power to controller and

modules.

Check/replace the ribbon cable from the

controller to the modules.

Check the voltage settings on the power

supplies.

Verify proper use of the software in the

operation manual.

Replace the controller.

(For direct displays) Check the signal cable

from the computer to the controller by doing a

loop back test. (See Appendix B)

Temperature always reads –

196F/-127C degrees F/ C

Check temperature sensor connections.

Replace the temperature sensor.