Troubleshooting, Troubleshooting -16, 9 troubleshooting – Daktronics AF-3165-34-RGB User Manual
Page 58

Maintenance and Troubleshooting
4-16
4.9 Troubleshooting
This sub-section contains some symptoms that may be encountered in the displays.
This list does not include every possible symptom, but does represent common
situations that may occur.
Symptom/Condition Possible
Cause/Remedy
One or more LEDs on a single
module fail to light.
•
Replace/check ribbon cables on the module.
•
Replace the module.
One or more LEDs on a single
module fail to turn off.
•
Replace/check ribbon cables on module.
•
Replace the module.
A section of the display is not
working. The section extends all
the way to the right side of the
display.
•
Replace/check the ribbon cable.
•
Check power to module.
•
Replace the first module/driver on the left side
of the first module that is not working.
•
Replace the second module that is not
working.
•
Replace the power supply assembly on the
first module that is not working.
One row of modules does not
work or is garbled.
•
Replace/check ribbon cable to first module.
•
Check for bent pins on module and controller
•
Replace first module.
•
Replace controller.
•
Check the fuses in the power termination box.
A group of modules, (a column of
block) which share the same
power supply assembly, fail to
work.
•
Check voltage to module.
•
Check the wire connections at the power
supply.
•
Replace the power supply assembly.
Entire display fails to work.
•
Check for proper line voltage into the power
termination panel.
•
Check fuse in power termination panel.
•
Check for correct power to controller and
modules.
•
Check/replace the ribbon cable from the
controller to the modules.
•
Check the voltage settings on the power
supplies.
•
Verify proper use of the software in the
operation manual.
•
Replace the controller.
•
(For direct displays) Check the signal cable
from the computer to the controller by doing a
loop back test. (See Appendix B)
Temperature always reads –
196F/-127C degrees F/ C
•
Check temperature sensor connections.
•
Replace the temperature sensor.
•
Replace the controller.