3.8 Signal Termination Between Two (or More) Signs

Reference Drawings:

System Riser Diagram Fiber........................................ Drawing A-174344

Schematic, Signal Wiring, Internal, W/QC ................... Drawing B-177662

RS422 Interconnection

The quick connect cable is the most common method
of terminating signal between two displays. The cable
goes from the RS422 OUT on the primary display to
the RS422 IN on the secondary display as shown in

Figure 32

.

Figure 32: Display Interconnection


If the displays are not back-to-back, or are too far
apart for the quick connect interconnect cable to reach,
a 4-conductor shielded cable of the correct length is
used. One end will connect at the “RS422 OUT” 6-
position controller board terminal block (A31-TB3) in
the first display, and terminate on the “RS422 IN” 6-
position controller board terminal block (A31-TB2) on
the second display. Refer to

Figure 33

. When not

using the quick inter-connect cable, wires must be
in conduit.

Figure 33: RS422 Interconnection

Electrical Installation

3-19