Conduit, Preparing for power/signal connection, Conduit -4 – Daktronics AF-3065-34-RGB User Manual
Page 20: Preparing for power/signal connection -4

3.4 Conduit
Reference Drawings:
System Riser Diagram, RS232.............................................................. Drawing A-96058
System Riser Diagram, RS422.............................................................. Drawing A-92681
System
Riser
Diagram, Modem............................................................. Drawing A-88426
System Riser Diagram, Fiber .............................................................. Drawing A-110559
Signal
Input, Venus 1500 .................................................................... Drawing A-129110
Entrance Box 8/16............................................................................... Drawing A-149160
Assy, Power Box 2/4 ........................................................................... Drawing A-155736
Shop
Drawing;
AF-3065-8-32 High...................................................... Drawing B-148418
Shop Drawing; AF-3065-40-48 High.................................................... Drawing B-148419
Daktronics does not include the conduit. Refer to Drawings B-148418 and B-148419 for approximate
locations for power and signal conduit. Separate conduit must be used to route:
·
Power
·
Signal IN wires
·
Signal OUT wires (if signal is required for another display)
Knockout holes for ½
² conduit are located at the bottom right (rear view) of the back of the display
(refer to Drawings B-148418 and B-148419).
L
For displays with more than one face, signal and temperature sensor wiring between displays can
be routed through the same conduit.
3.5
Preparing for Power/Signal Connection
Reference Drawings:
System Riser Diagram, RS232.............................................................. Drawing A-96058
System Riser Diagram, RS422.............................................................. Drawing A-92681
System
Riser
Diagram, Modem............................................................. Drawing A-88426
System Riser Diagram, Fiber .............................................................. Drawing A-110559
Signal Input, Venus 1500 .................................................................... Drawing A-129110
Entrance Box 8/16............................................................................... Drawing A-149160
Power Connection, AF-306X ............................................................... Drawing A-154965
Assy, Power Box 2/4 ........................................................................... Drawing A-155736
Shop
Drawing;
AF-3065-8-32 High...................................................... Drawing B-148418
Shop Drawing; AF-3065-40-48 High.................................................... Drawing B-148419
Detail drawing, Controller and Power Term 24-48 High....................... Drawing B-156686
Component Layout Diagram........................................................................... Appendix B
Schematic ...................................................................................................... Appendix B
1. Punch or use
f² (0.875) conduit holes for the desired conduit openings. Be careful that none of
the internal components are damaged. Refer to Drawings B-148418 and B-148419. Attach the
conduit.
2. Remove the bottom left two modules (AX01 and AX02) to expose the power enclosure and signal
panel. To do this, use a nut driver or
c² Allen wrench to turn the latch access fasteners one-
quarter turn. Turn the top latch clockwise and the bottom latch counter-clockwise. Lift each
module away from the display; reach behind it and disconnect all power and signal connections.
3. Locate the controller and power termination box for these displays in the Component Layout
Diagram. The controller is shown in Figure 2. The controller receives the incoming signal and
relays it to the individual modules.
Electrical Installation
3-4