beautypg.com

Daktronics Outdoor LED Scoreboards Installation User Manual

Page 52

background image

REV

01

DATE:

8 JAN 14

ADDED ALLOWABLE TENSION AND SHEAR CAPACITY DETAILS

ADDED NON-BKLT AD PANEL MOUNTING DETAILS

CHANGED DWG TO B SIZED.

BY:

JAVA

DAKTRONICS, INC.

THE CONCEPTS EXPRESSED AND DETAILS SHOWN ON
THIS DRAWING ARE CONFIDENTIAL AND PROPRIETARY.
DO NOT REPRODUCE BY ANY MEANS WITHOUT THE
EXPRESS WRITTEN CONSENT OF DAKTRONICS, INC.
COPYRIGHT 2014 DAKTRONICS, INC.

BROOKINGS, SD 57006

DO NOT SCALE DRAWING

PROJ:

OUTDOOR SCOREBOARD

TITLE:

I-BEAM CLAMP MOUNTING, SHEET METAL ATTACHMENT

DESIGN:

KSCHNABEL

DRAWN:

KSCHNABEL

DATE:

06-JAN-14

SCALE:

1/8

SHEET:

REV

JOB NO:

FUNC-TYPE-SIZE

1129110

1 OF 1

01

P 1753

E

-

10

-

B

MOUNTING INSTRUCTIONS:

1. LIFT THE FIRST SECTION OF THE DISPLAY INTO POSITION
AGAINST I-BEAMS.
NOTE: IF THE DISPLAY IS MADE UP OF MULTIPLE SECTIONS
ALWAYS INSTALL THE BOTTOM SECTION FIRST AND WORK UP.
2. STARTING ON THE TOP OF THE SECTION BEING INSTALLED
MARK AND DRILL 9/16" HOLES IN THE CENTER OF THE TOP
FLANGE OF THE SECTION. MAKE SURE THE HOLES ARE
POSITIONED AS CLOSE TO THE I-BEAM FLANGES AS POSSIBLE.
3. INSTALL ALL THE HARDWARE SHOWN PROVIDED AND TIGHTEN
THE SECTION IN THE DESIRED LOCATION.
4. ONCE THE TOP OF THE SECTION IS SECURE MOVE TO THE
BOTTOM OF THE SECTION AND REPEAT THE STEPS ABOVE.
5. IF THE DISPLAY IS MADE OF MULTIPLE SECTIONS REPEAT
THE ENTIRE PROCEDURE ABOVE.
6. ENSURE ALL 1/2" HARDWARE IS TORQUED TO THE SPECIFIED
AMOUNT.

STANDARD SHEETMETAL SCOREBOARD/BACKLIT
AD PANEL MOUNTING METHOD

ALLOWABLE CAPACITY PER EACH CLAMP:

SHEAR = 160 LBS

TENSION = 1700 LBS

SHEAR AND TENSION LOAD

DIRECTION ARE AS INDICATED ON

ROTATED VIEWS

STANDARD NON-BACKLIT AD PANEL MOUNTING METHOD

QUALIFIED FOR SECTIONS UP TO 5' IN HEIGHT

USING RECOMMENDED STRUCTURE

FRONT ROTATED VIEW

1/2-13 SQUARE NUT

WASHER PLATE @2

MOUNTING CHANNEL

1/2" SPLIT LOCK WASHER

1/2" FLAT WASHER

I-BEAM CLAMP

#12-14 X 1.500" SELF DRILLING SCREW

1/2-13 X 3.500 BOLT

TENSION

SHEAR-X

SHEAR-Y

FRONT OF SECTION

SECTIONS

VERTICAL BEAM - RECOMMENDED FLANGE THICKNESS 3/16" - 3/4"
IF I-BEAM FLANGE IS GREATER THAN 3/4" THICK LONGER BOLTS
WILL BE REQUIRED AT THE CUSTOMER'S EXPENSE.

1/2-13 X 3.500 BOLT - BOLT THREAD MUST ENGAGE ENTIRE DEPTH
OF SQUARE NUT. BOLT MUST BE TIGHTENED TO 40FT-LB TORQUE

1/2" SPLIT LOCK WASHER

1/2" FLAT WASHER

I-BEAM CLAMP - ASSURE CLAMP IS TIGHTLY ENGAGED
TO I-BEAM AND NUT

1/2-13 SQUARE NUT

1/8" THICK WASHER PLATE @2 - IT IS CRITICAL 2 WASHER
PLATES ARE USED PER HARDWARE ASSEMBLY

MOUNTING CHANNEL WITH OBROUND SLOTS - CENTER THE
CHANNEL 0N THE I-BEAM AS MUCH AS POSSIBLE

#12-14 X 1.500" SELF DRILLING SCREW - INSERT SCREW UNTIL
HEAD CONTACTS BEAM CLAMP. DO NOT STRIP OUT SCREW.

TOP VIEW

1/2-13 SQUARE NUT

WASHER PLATE @2

MOUNTING CHANNEL

1/2" SPLIT LOCK WASHER

1/2" FLAT WASHER

I-BEAM CLAMP

#12-14 X 1.500" SELF DRILLING SCREW

1/2-13 X 3.500 BOLT

TENSION

SHEAR-X

SHEAR-Y

REAR ROTATED VIEW

VERTICAL BEAM - RECOMMENDED FLANGE THICKNESS 3/16" - 3/4"
IF I-BEAM FLANGE IS GREATER THAN 3/4" THICK LONGER BOLTS
WILL BE REQUIRED AT THE CUSTOMER'S EXPENSE.

1/2-13 X 3.500 BOLT - BOLT THREAD MUST ENGAGE ENTIRE DEPTH
OF SQUARE NUT. BOLT MUST BE TIGHTENED TO 40FT-LB TORQUE

1/2" SPLIT LOCK WASHER

1/2" FLAT WASHER

I-BEAM CLAMP - ASSURE CLAMP IS TIGHTLY ENGAGED
TO I-BEAM AND NUT

1/2-13 SQUARE NUT

1/8" THICK WASHER PLATE @2 - IT IS CRITICAL 2 WASHER
PLATES ARE USED PER HARDWARE ASSEMBLY

MOUNTING CHANNEL WITH OBROUND SLOTS - CENTER THE
CHANNEL 0N THE I-BEAM AS MUCH AS POSSIBLE

#12-14 X 1.500" SELF DRILLING SCREW - INSERT SCREW UNTIL
HEAD CONTACTS BEAM CLAMP. DO NOT STRIP OUT SCREW.

TOP VIEW

FRONT OF SECTION

SECTIONS