Electrical Installation

Refer to Figure 27 for internal power/signal connection guidelines between a T.O.L. section
and its mating HOME/GUEST section.

Refer to Figure 28 for internal power/signal connection guidelines between DOWN/TO GO
and BALL ON/QTR sections.

For sections that are too far apart to use internal interconnects, the signal may be re-driven, or
“daisy-chained”. Typically, the Game Clock section would receive primary signal from the
control location, and signal cable could then branch out to the HOME score and GUEST score
sections. From there, signal can be re-driven once more to the DOWN/TO GO and BALL
ON/QTR sections. Refer to Figure 29 for an example of re-driving signal.

Note: For radio-controlled systems, the radio receiver may be located in one section,
while signal cable is routed to the other sections as needed.



Figure 27: T.O.L. Power/Signal Interconnections (Front View)

Figure 28: BALL ON/QTR Power/Signal Interconnections (Front View)