TNMC Maintenance

9-9

Symptom/Condition

Possible Cause/Remedy

Entire display fails to work.

§ Check for proper line voltage into the power

termination panel.

§ Check/replace the ribbon cable from the controller

to the modules.

§ Check the voltage settings on the power supplies.

§ Check/replace the signal cable to the controller.

§ Replace the controller.

§ Verify proper use of the software in the operation

manual.

Temperature always reads 32
degrees F/0 degrees C.

§ Check temperature sensor connections.

§ Replace the temperature sensor.

§ Replace the controller.

Display is stuck on bright or dim.

§ Check manual/auto dimming in the Venus 1500

software.

§ Check the light detector cable.

§ Check the light detector for obstructions.

§ Replace the light detector.

§ Replace the controller.

9.8 Initialization Information at Startup

Every time the display is powered up, the display will run through an initialization in which it will
test all LEDs and addresses. When completed, the initialization test will display Home and Guest in
the appropriate location.

9.9 Replacement Parts List

The following table contains some of the TNMC components that may require replacement over the
life of a display. Many of the components within the display also have attached part number labels.

Part Description

Part Number

Controller II

0A-1146-0061

Current loop interface card

0A-1146-0016

Module; 3R, 8x8 coated type 1 (red, 3 LED/Pixel)

0A-1208-3002

Power supply with harness (1, A-1633)

0A-1213-2039

Power supply with harness (1, A-1555)

0A-1213-2011

Power supply assembly (2, A-1555)

0A-1213-2043

Modem jack; 6-pin female

J-1094

Cable; 18” RJ-11; 6-conductor

0A-1137-0160

Ribbon cable; 40-conductor, 30 AWG (controller to
module, module to module

W-1412

Cable; 22 AWG

W-1234

Electrical contact cleaner/lubricant (CaiLube)

CH-1020