1 - operational modes – Code CR1200 User Manual
Page 21
C003525_06_CR1200_User_Manual
16
Save Settings
4.1 - Operational Modes
The CR1200 can operate in either of two modes:
•
Triggered (default mode)
•
Continuous Read
In Triggered mode, the CR1200 reads a code in response to a trigger press. In Continuous Read mode the CR1200
continuously attempts to read a code without operator intervention. Continuous Read mode includes options to
specify delays between attempts to read and to limit the duplicate readings of the same code.
4.2.1 - Continuous Read Mode
Read the following codes to turn continuous reading on or off:
Continous Scan - On
Continous Scan Off (Default)
4.2.1.1 - Read Delays
Read the following codes to set delay time between reads:
0 Seconds (Default)
1 Second
3 Seconds
4.2.1.2 - Duplicate Rejection Period
The Duplicate Rejection Period defines a time interval. If a read during this interval duplicates the immediately preced-
ing code, the read will be rejected. Read the following codes to set the delay time before the reader accepts a dupli-
cate code:
0 Seconds (Default)
1 Second
3 Seconds