Safety Considerations and Information

The unit must be earthed. Ensure that the mains power supply provides an effective
earth connection using a three-wire termination.
When the mains switch is in the off (‘O’) position the live and neutral conductors of

the mains transformer are disconnected.

CAUTION – High Voltages

Do not touch any part or terminal carrying the hazardous live symbol ( ) while
power is supplied to the unit.
Terminals to which the hazardous live symbol refers require installation by a qualified
person.

CAUTION - Mains Fuses

The MA60 and MA60

media

mixer-amplifiers are fitted with a replaceable mains fuse.

This is located on the rear panel below the AC mains input connector. Only replace
the fuse with one of an identical type and rating.

AC VOLTAGE

FUSE TYPE

FUSE RATING

230 V or 115 V

20 mm x 5 mm, T2A

2 amp

Note that the failure of the mains fuse may indicate an internal fault. If a replacement
fuse fails immediately the power is restored, no further attempt should be made to use
the mixer-amplifier, and it should be returned to your Cloud service centre or other
qualified person for repair.

CAUTION – Servicing

The unit contains no user serviceable parts. Refer servicing to qualified service
personnel. Do not perform servicing unless you are qualified to do so.
Disconnect the power cable from the unit before removing the top panel and do not
make any internal adjustments with the unit switched on.