Table of internal jumpers and default settings – Cloud Electronics 46-120TMedia User Manual
Page 31
46-120 Installation and User Guide V1.2
31
Table of internal jumpers and default settings
JUMPER
LOCATION
DESCRIPTION
EFFECT
DEFAULT
J1
Main board
Mic 1 phantom power
OFF: MIC 1 phantom power OFF
ON: MIC 1 phantom power ON
OFF
J2
Main board
Mic 2 phantom power
OFF: MIC 2 phantom power OFF
ON: MIC 2 phantom power ON
OFF
J3
Main board
Zone 1 65 Hz High Pass Filter
OFF: full frequency response
ON: 65 Hz hi-pass filter enabled for Zone 1
OFF
1
J4
Main board
Zone 2 65 Hz High Pass Filter
OFF: full frequency response
ON: 65 Hz hi-pass filter enabled for Zone 2
OFF
1
J5
Main board
NO/NC Mute contacts
N/O: contact closure required for muting
N/C: contact opening required for muting
N/O
J6
Mic Control sub-
board
Mic over music priority
OFF: No priority – mics mix with music
ON: Music ducks when mics in use
ON
J7
Main board
Mic over Facility input priority
OFF: No priority
ON: MIC 1 & 2 have VOX-triggered priority over
signals at facility port
OFF
J8
Main board
Zone 3 65 Hz High Pass Filter
OFF: full frequency response
ON: 65 Hz hi-pass filter enabled for Zone 3
OFF
1
J9
Main board
Zone 4 65 Hz High Pass Filter
OFF: full frequency response
ON: 65 Hz hi-pass filter enabled for Zone 4
OFF
1
J10
Main board
Mic1, Zone 1 Access Bypass
PRESENT: Mic 1 has permanent access to Z1
ABSENT: Use access port to enable access to Z1
ON
J11
Main board
Mic1, Zone 2 Access Bypass
PRESENT: Mic 1 has permanent access to Z1
ABSENT: Use access port to enable access to Z2
ON
J12
Main board
Mic1, Zone 3 Access Bypass
PRESENT: Mic 1 has permanent access to Z1
ABSENT: Use access port to enable access to Z3
ON
J13
Main board
Mic1, Zone 4 Access Bypass
PRESENT: Mic 1 has permanent access to Z1
ABSENT: Use access port to enable access to Z4
ON
J14A, B3
Music Control sub-
board
Zone 1 Line 6 priority
OFF: No priority
ON: Line 6 has VOX-triggered priority over other
sources in Zone 1
OFF
J15
Line input sub-board
Zone 1 Line 6 priority release time
3S: 3 seconds. release time
6S: 6 seconds release time
ABSENT: 12 seconds release time
6S
J16
Music Control sub-
board
MOH/Utility source select
L1: MOH/Utility output always Line 1 input
L2: MOH/Utility output always Line 2 input
L3: MOH/Utility output always Line 3 input
L4: MOH/Utility output always Line 4 input
L5: MOH/Utility output always Line 5 input
L6: MOH/Utility output always Line 6 input
MP3: L1: MOH/Utility output always media player
2
Z1: MOH/Utility output follows Zone 1 selection
Z1
J17A, B, C
3
Main board
MIC 1/TEL input transformer
OFF: MIC 1 input accepts standard mics
ON: MIC 1 input suitable for connection to
telephone system
OFF
J18A, B, C
Main board
Auto Power down time
Binary weighting applies: see table at page 25.
OFF (APD
disabled)
1. On models 46-120T and 46-120T
MEDIA
, default setting is ON.
2. Operative on Models 46-120
MEDIA
and 46-120T
MEDIA
only.
3. All jumpers in the set must be moved together.