Factory settings – Beisler 2112-4 User Manual
Page 99

- D 99 -
Short Seam Automat 2112-4 Working Instructions
Beisler Automated Sewing Equipment
D.4
Factory settings
D.4.1 Factory settings global parameters
M 01 global parameters 2112-4:
Pos.
Globalparameter 2112-4
Value
Unit
01
TILL CLAMP SIDEWAYS FWD
0.1
sec
02
TILL CLAMP DOWN
0.1
sec
03
TILL VACUUM OFF
0.1
sec
04
THRD LENGTH,BOBBIN FULL
003
m
05
TILL CLAMP INSERTING
0.1
sec
06
SEWING END ->CL.SIDEW.
0.1
sec
07
TIME AFTER CLAMP OPEN
0.1
sec
10
TILL FOLDING CL. CLOSED
0.5
sec
11
TILL FOLDER LIFT UP
0.2
sec
12
TILL FOLDER SWINGS LEFT
0.2
sec
13
IMPULS FOLDER DOWN
0.05
sec
14
CL.OPEN TILL FOLDER UP
0.20
sec
17
TILL TENSION OPEN
0.00
sec
18
DURATION OF TENS. OPEN
0.4
sec
20
DUR.THREAD CLAMP FORW
0.5
sec
21
TILL STACKER TRANSPORT
0.1
sec
22
DUR.SLIDING TABLE OPEN
0.8
sec
23
LIFT.TABLE MOD 00/01-99
0
24
DUR.LIFTING TABLE SINKS
0.99
sec
25
TILL FABRIC CLAMP FORW.
0.0
sec
26
TILL SCISSORS CLOSED
0.0
sec
27
DURATION SCISSORS CUTS
0.0
sec
28
TILL FABRIC CLAMP OPEN
0.0
sec
32
BLOW OUT THE PART
0.5
sec
33
CLAMP MOVES TO STACKER
0.0
sec
35
THREAD CATCH. "UP" POS
200
INC
36
SWITCH ON POS.OF TRIMM.
100
INC
37
TRIMMING SPEED
180
Upm
38
DURATION OF TRIMMING
0.35
sec
39
THREAD CATCH.TURNS BACK
00
INC
40
PROCESS IN STEPS
00