5. Electrical Interface Characteristics

Parameter

Symbol

Min.

Typ.

Max.

Unit

Note

Transmitter
Total Supply Current

I

CC

A

mA

Note

(1)

Differential Data Input Swing

V

DT

500 2400

mV

p-p

Differential line input Impedance

R

IN

80

100

120

Ohm

Data Input Voltage- High

V

IH

-V

CC

-1.165

-0.880

V

Data Input Voltage- Low

V

IL

-V

CC

-1.810

-1.475

V

Transmitter Disable Input-High

V

DISH

2 V

CC

V

Transmitter Disable Input-Low

V

DISL

0 0.8 V

Transmitter Fault Output-High

V

TXFH

2

V

CC

+0.3

V

Transmitter Fault Output-Low

V

TXFL

0 0.8 V

Transmitter Fault Pull up Resistor

R

TX_FAULT

4.7

10

kΩ Note

(2)

Receiver
Total Supply Current

I

CC

B

mA

Note

(1)

Differential Data Output Swing

V

DR

400 2000

mV

p-p

Note

(3)

Data Output Voltage-High

V

OH

-V

CC

-1.085

-0.880

V

Data Output Voltage-Low

V

OL

-V

CC

-1.830

-1.555

V

LOS Output Voltage-High

V

LOSH

2

V

CC

+0.3

V

LOS Output Voltage-Low

V

LOSL

0 0.8 V

Receiver LOS Load

R

RXLOS

4.7 10 kΩ Note

(2)

Note (1). A (TX)+ B (RX) = 250mA (Not include termination circuit)
Note (2). Pull up to V

CC

on host Board.

Note (3). Internally AC coupled, but requires a 100Ohm differential termination at or internal to Serializer/

Deserializer.


6. Timing of Control and Status I/O

Parameter

Symbol

Min.

Max.

Unit

Unit Conditions

TX_DISABLE Assert
Time

t_off

10

µsec

Time from rising edge of TX_DISABLE to
when the optical output falls below 10% of
nominal

TX_DISABLE
Negate Time

t_on

1

msec

Time from falling edge of TX_DISABLE to
when the modulated optical output rises above
90% of nominal

Time to initialize,
including reset of
TX_FAULT

t_init

300

msec

From power on or negation of TX_Fault using
TX_Disable.

TX_Fault Assert Time

t_fault

100

µsec Time from fault to TX_Fault on.

TX_DISABLE to
reset

t_rest 10

µsec

Time TX_Disbale must be held high to reset
TX_Fault

LOS Assert Time

t_loss_on

100

µsec Time from LOS state to Rx LOS assert

LOS Deassert Time

t_loss_off

100

µsec Time from non-LOS state to Rx LOS deassert

Serial ID Clock Rate f_serial_clock 100

kHz