Service Manual Full Size Sensor

11/07

Rev. 1.03

6

Media limitation

Please watch carefully, that the full size sensor can only be used with cardboard material
(notched) ! The sensor is a digital sensor – means only 0 and 1 – self adhesive media can
not be used.


The

minimum media width

– used with the full size sensor – has to be

36 mm

! If the full size

sensor is mounted to the unit – as well the standard sensor can not be used for smaller
material.

The optional full size sensor can be moved from

Printer

can be moved from - to (mm)

TTX 450

16 – 93

TTX 650

16 – 134

TTX 950

16 – 165

Unpack


Normally the full size sensor is supplied mounted to the printer (installed) ! If this is not the
case – the option can be retrofitted by a service technician !

Attention:

To activate the sensor please follow the instruction shown in chapter set up
mode.



Please check if all parts are delivered

2

additional

axle

1

outer

side

plate

1

inner

side

plate

1 steal part inner

1 sensor assy. ( 2 parts – 1 cable)

1 outer media guiding