Service Manual Full Size Sensor

11/07

Rev. 1.03

15

Initialise or activate option


After you have mounted the option correctly to the printer - and the necessary adjustment
the option can be activated

This can be done by changing the parameter in the Firmware.


















• switch on the unit

display shows

OFF

• press FEED and CUT at the

display shows

INFO

same time
• press CUT until

display shows

SYSP

press

ENTER display

shows

EMUL

• press CUT until

display shows

SENS

select

until

display

shows

FULL

• press ENTER to accept

beep

• press FEED and CUT

display shows

SYSP

• press FEED and CUT

display shows

OFF

Attention:

The option is now activated - all other option’s are deactivated!


Check Sensor



The sensor of the full size sensor – used to detect the presence of a label – can be
checked.

Select in the printer menu the function SCHK – go to menu point U xx and test the function
of the sensor.

Without media a shown in the display

‚U 0‘


with

media

is

shown

‚U 15‘