MPCL Error Codes

This appendix lists MPCL error codes. The following table lists
the codes in numerical order, followed by an explanation of the
code’s meaning.

Code Explanation

01

The format ID is out of range. Use a number from 1 to
99.

04

The format length has exceeded the maximum feed
length (9 inches).

05

The format width has exceeded the physical limit (4.23
inches).

10

The field number is out of range. Use a number from
1 to 30.

11

The number of characters in the field is out of range.
Use a number from 1 to 30.

12

The field’s row position is out of bounds. The image
length is 8 inches.

13

The field’s column position is out of bounds. The
maximum image width is 4 inches.

15

Invalid character rotation. Enter 0 (for 0-degree
rotation), 1 (for 90-degree rotation), 2 (for 180-degree
rotation), or 3 (for 270-degree rotation).

16

Invalid field rotation. Enter 0 (for 0-degree rotation), 1
(for 90-degree rotation), 2 (for 180-degree rotation), or
3 (for 270-degree rotation).

17

The field number is out of sequence. All numbered
fields must be in sequential order.

20

Invalid vertical magnification. Use a number from 1 to
7.

M

P

CL
E
rro

r

Co
d

e

s

A-1