Avery Dennison Monarch 9860 Programmer Manual Addendum2 User Manual
Page 4

B8. density
Bar code density. The range is 2-8. The default is 2.
Select the density from the following table.
Bar Code
Type
Density
Selector
203 dpi
Narrow
Element Size
(dots/mils)
300 dpi
Narrow
Element Size
(dots/mils)
Data
Length
Char
Set
2
2/9.9
3/9.8
3
3/14.8
4/13.1
4
4/19.7
5/16.4
5
5/24.6
7/23
6
6/29.6
8/26.2
7
7/34.5
10/32.8
GS1
DataBar
8
8/39.4
11/36.1
0-2710
00H
to
FFH
B9. height
Bar code height of the linear bar code, in 1/100 inches,
1/10 mm, or dots. Minimum values:
English
19
Metric
48
203 Dots
38
300 Dots
57
Note:
Only for use with UCC/EAN family types listed
below.
B10. text
Appearance of text with bar code. Options:
0 Default
8
No text, bar code only
B11. alignment
Alignment of bar code data in the field. Use L (left).
B12. field rot
Field rotation. Field rotation rotates the whole field.
Rotation is affected by the pivot point, which varies
depending on how text is justified. The lower left corner
of the field is the pivot point. The default is 0. Options:
0
Top of field points to top of supply
1
Top of field points to left of supply
2
Top of field points to bottom of supply
3
Top of field points to right of supply
4