beautypg.com

Vent requirements, Vent installation, Nsert – Avalon Firestyles DVS Insert-1996 to 2000 User Manual

Page 9: Nstallation

background image

I

NSERT

I

NSTALLATION

(C

ONT

.)

- For Qualified Installers Only!

P

AGE

9

Vent Requirements

!

The gas appliance and vent system must be vented directly to the outside of the building, and never
be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas
appliance must use it's own separate vent system.

!

Make sure the exhaust pipe on the heater connects to the exhaust portion of the cap. The illustrations
below show how the flex liners should be attached.

¥

The exhaust vent must reline the entire length
of the chimney and terminate above the
chimney top

!

If the heater is installed at an altitude over
3,000' (914 M) the flame quality will need to
be carefully evaluated. See Addendum #1,
"Altitude Considerations"(page 35).

!

Be careful not to crimp or rupture the liner
when bending it into chimney offsets

¥

When installed, the vent must meet all of the
vent manufacturer's requirements

¥

Make sure to order the following:

¥ 3" (75 mm) UL 1777 Gas Liner

¥ Dura-Vent Adapter & Flashing (part #

923GK).

¥ Vertical Termination (part # 991)

Max. 1'
(305
mm)
offset

Max. Ht. 35' (10.7 M)
Min. Ht. 8' (2.4 M)

Inlet

Exhaust

Vent Installation

Inlet

Exhaust

Inlet

Exhaust

Termination
(Simpson
Part # 991)

DV Chimney
Liner Kit
(Simpson Part
# 923GK)

3Ó (75 mm)
UL 1777
Gas Liner

High-Temp.

Silicone

Apply high-temperature
silicone to the liners on
both ends and secure
with 2 screws.

Make sure to route the exhaust liner to the exhaust portion of the cap.

High-Temp.

Silicone