beautypg.com

Listing information, Isting, Nformation – Avalon Firestyles DVS Insert-1996 to 2000 User Manual

Page 27: Minimum clearances to combustibles

background image

L

ISTING

I

NFORMATION

P

AGE

27

The safety label can be found on the card behind the control cover. A copy is shown below.

DVS Insert

Listed Gas-Fired Direct V

ent Fireplace Insert

Suitable For Installation Into Masonry

or Factory-Built (Z.C.) Fireplaces

Tested and certified by OMNI-T

est, Inc. to the following standards:

USA:

ANSI Z21.44 Gas-Fired Gravity and Fan type Direct-V

ent W

all Furnace, and applicable sections of Z21.1

1.1 Gas-Fired V

ented R

oom Heaters.

CANADA:

CAN 1-2.19-M81 Gas-Fired Direct-V

ent W

all Furnace, CGA

IR41 Direct-V

ent Gas Fireplace, CGA

IR55 additional requirements fo

r Direct-V

ent Fireplaces,

and CAN/CGA

2.17-M91 “Gas-Fired

Appliances for use at High

Altitudes”.

Must be installed in accordance with all local codes, if any; if not, follow

ANSI Z223.1-1992 and NFP

A

54(88). Installation in M

anufactured or Mobile Homes must

conform with: In USA, Manufactured Home Construction and Safety Standard, T

itle 24 CFR, Part 3280; In Canada, CSA

Z240.4 and Gas

-Equipped Recreational

V

ehicles and Mobile Housing. The 36DV is designed to operate on natural gas, or propane (LP). This appliance uses a millivolt-t

ype control system consisting of a

gas control valve/regulator

, a standing pilot burner assembly

, a thermopile, a piezo ignitor

, and the ON/OFF switch. THIS UNIT

DOES NOT REQUIRE 1

10 VOL

T POWER

TO

OPERA

TE.

All exhaust gases must be vented outside the structure of the living-area. Combustion air is drawn from outside the

living-area structure. This

appliance may be installed in Manufactured Housing only after the home is site located.

W

ARNINGS:

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the informa

tion in the owner

’s

and installation manual

provided with this appliance. For assistance or additional information consult a qualified installer

, service agency or the gas

supplier

.

Installation and repair should be performed by a qualified service person. The appliance should be inspected before use and at

least annually by a qualified service

person. More frequent cleaning may be required where excessive lint from material like carpeting and bedding is present. The co

ntrol compartment, the burner

compartment and all circulating air passageways of the appliance must be kept clean and clear at all times.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies

This appliance must not be connected to a chimney flue servicing a separate solid fuel burning appliance.

This room heater is a Direct-V

ent Gas-Fired appliance. DO NOT burn wood or other material in this heater

.

Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid flesh burns or c

lothing ignition.

Young children should be carefully supervised at all times when they are in the same room as the appliance.

CAUTION:

All safety screen or guard components removed for servicing, must be replaced prior to operating the appliance.

Clothing or other flammable material should not be placed on or near the appliance.

Risk of electrical shock. Switch the household breaker off or remove fuse before servicing unit.

Use Simpson DURA-VENT direct vent system (Model GS) to vent this appliance to the exterior (direct discharge only without duct

connection).

Beaverton,

OR. USA

T

ested &

Listed by

10850 1

17th Pl. N.E. Kirkland, W

A

98033

Minimum Clearances to Combustibles

Faceplate to Sidewall

..........................

6”

Mantle Height

Above Faceplate

..................

10”

Front of Unit

........................................

36”

Side Facing to Faceplate

.............................

6”

Top Facing to Faceplate

..............................

8”

Hearth Extension Front

...............................

12”

Hearth Extension Sides

...............................

0”

L.P
.

N.G.

L.P
.
N.G.

Input Rate on “HI” (BTU/Hr)*

. . . . . .

31,000

31,000

Minimum Inlet Pressure (inches W

.C.)

. . . . . . . .

11”

5.5”

Input Rate on “LO” (BTU/Hr)*

. . . . .

16,000

18,600

Maximum Inlet Pressure (inches W

.C.)

. . . . . . . .

13”

7”

Main Burner Orifice (DMS)*

. . . . . . .

.0625

#37

Manifold Pressure on “HI” (inches W

.C.)

. . . . . .

10”

3.5”

Manifold Pressure on “LO” (inches W

.C.)

. . . . .

2.7”

1”

This room heater is equipped at the factory for use with natural gas. If conversion to propane (LP) fuel is desired the

optional factory conversion kit must be used.

Blower Electrical Rating:

115v
, 1.5

Amps, 60 Hz F

AN TYPE VENTED CIRCULA

T

O

R

Manufacture

1996

Jan.

Apr
.

Jul.

Oct.

Date:

1997

Feb.

May

Aug.

Nov

.

1998

Mar

.

Jun.

Sep.

Dec.

IGN

Report No. 028-S-15-5