Pilot flame inspection, Inalizing the, Nstallation – Avalon Firestyles DVS Insert-1996 to 2000 User Manual
Page 16: Cont

P
AGE
16
F
INALIZING THE
I
NSTALLATION
(
CONT
.)
- For Qualified Installers Only!
4
Replace the glass. Make sure the glass is centered, the gasket remains in place, and the glass forms
an air-tight seal. Tighten the glass clips to secure the glass. See the illustration on page 14.
5
Turn on gas to the heater. Leak test all gas joints prior to starting the appliance. Start the pilot. Start
the main burner. Leak test all gas joints again.
6
Check the pilot flame to make sure it looks like the illustration below. Adjust the pilot flame if
necessary.
The pilot flame should impinge the top 3/8Ó (10 mm)
of the thermopile. If it does not, you may need to
turn the pilot up.
3/8Ó (10 mm)
Thermopile
Pilot Hood
Thermocouple
To adjust the pilot flame, remove the cover screw (and
gasket) and turn the needle valve. Clockwise lowers
the flame while counter-clockwise raises it.
PILOT ADJ
T
O
L
PI
ON
OFF
Standard
Screwdriver
Micro (1/16Ó)
Standard
Screwdriver
The cover screw and
gasket must be
replaced to prevent gas
from leaking
Cover Screw
Cover Screw Gasket
Needle Valve