beautypg.com

Pilot flame inspection, Inalizing the, Nstallation – Avalon Firestyles DVS Insert-1996 to 2000 User Manual

Page 16: Cont

background image

P

AGE

16

F

INALIZING THE

I

NSTALLATION

(

CONT

.)

- For Qualified Installers Only!

4

Replace the glass. Make sure the glass is centered, the gasket remains in place, and the glass forms
an air-tight seal. Tighten the glass clips to secure the glass. See the illustration on page 14.

5

Turn on gas to the heater. Leak test all gas joints prior to starting the appliance. Start the pilot. Start
the main burner. Leak test all gas joints again.

6

Check the pilot flame to make sure it looks like the illustration below. Adjust the pilot flame if
necessary.

The pilot flame should impinge the top 3/8Ó (10 mm)
of the thermopile. If it does not, you may need to
turn the pilot up.

3/8Ó (10 mm)

Thermopile

Pilot Hood

Thermocouple

To adjust the pilot flame, remove the cover screw (and
gasket) and turn the needle valve. Clockwise lowers
the flame while counter-clockwise raises it.

PILOT ADJ

T

O

L

PI

ON

OFF

Standard
Screwdriver

Micro (1/16Ó)
Standard
Screwdriver

The cover screw and
gasket must be
replaced to prevent gas
from leaking

Cover Screw

Cover Screw Gasket

Needle Valve