Commands and responses table, Error responses – Analog Way Studio Scan XTD620 User Manual
Page 18

Chapter 10 : RS-232 PROGRAMMER'S GUIDE STUDIO SCAN XTD 620
PAGE 18
10-2. COMMANDS AND RESPONSES TABLE
The following table resumes commands which are recognized as valid and the responses that will be returned to the host
(on RS-232 port).
VALUE
EXAMPLES
ASCII
COMMAND
RESPONSE
TO HOST
COMMAND
DESCRIPTION
MIN
MAX
COMMAND
RESPONSE
ACTION
EXPLANATION
Image commands
H
Hpo
Horizontal positioning
0
255
20H
Hpo20
Set Hpos to 20
V
Vpo
Vertical positioning
0
255
V
Vpo73
Read V position
W
Hsz
Horizontal width
0
255
W
Hsz128
Read H width
S
Vsz
Vertical size
0
255
157S
Vsz157
Set Vsize
h
Hpn
Horizontal panning
0
255
128h
Hpn128
Set H panning
v
Vpn
Vertical panning
0
255
v
Vpn102
Read V panning
w
Hzm
Horizontal zoom factor
0
255
100w
Hzm100
Set H zoom
s
Vzm
Vertical zoom factor
0
255
150s
Vzm150
Set V zoom
Output commands
* T
TSO
Output standard
0
63
T
TSO33
Read Output standard
F
FLK
Filter Flicker level
0
7
4F
FLK4
Set to level # 4
N
BLV
Black level
0
255
N
BLV128
Read Black level
R
REDLV
Red level
0
255
106R
REDLV106
Set Red level
G
GRELV
Green level
0
255
G
GRELV128
Read Green level
B
BLULV
Blue level
0
255
B
BLULV127
Read Blue level
Genlock controls
k
GLK
Genlock status
0
2
k
GLK0
Read Genlock status
I
SCPH
Sub carrier phase setting
0
1023
522I
SCPH522
Set SC Ph
i
HPHI
Horizontal Sync phase setting
0
255
138i
HPHI138
Set H Ph
Input status (Read only)
d
DHI
Horizontal period of input
signal
0
65535
d
DHI564
Read line frequency
l
GRT
Number of line per field
0
65535
l
GRT525
Read line per field
* t
TSY
Sync type
0
255
t
TSY113
Read Sync type
u
UNIT
Measures unity in kHz
0
65535
u
UNIT17734 Read unity of measures
Miscellaneous
* c
MISC
Miscellaneous controls
0
31
c
MISC0
Read controls
* b
BP
Front panel actions
0
31
8b
BP8
Set Freeze mode
?
DEV
device type
0
2
?
DEV1
Read device type
M
M_
"M" Firmware Version
0
65535
M
M_13316
Read "M" Version
L
L_
"L" Firmware Version
0
65535
L
L_18915
Read "L" Version
r
R_
"R" Firmware Version
0
65535
r
R_57427
Read "R" Version
* See Chapter 10-4 COMMANDS DESCRIPTION
10-3. ERROR RESPONSES
When the STUDIO SCAN receives from the host an invalid command or value, it returns an error response:
E10
↵
invalid command (See : "Command" Column)
E13
↵
invalid value (See "Value" Column)