beautypg.com

Commands and responses table, Error responses – Analog Way Studio Scan XTD620 User Manual

Page 18

background image

Chapter 10 : RS-232 PROGRAMMER'S GUIDE STUDIO SCAN XTD 620


PAGE 18

10-2. COMMANDS AND RESPONSES TABLE

The following table resumes commands which are recognized as valid and the responses that will be returned to the host
(on RS-232 port).

VALUE

EXAMPLES

ASCII

COMMAND

RESPONSE

TO HOST

COMMAND

DESCRIPTION

MIN

MAX

COMMAND

RESPONSE

ACTION

EXPLANATION

Image commands

H

Hpo

Horizontal positioning

0

255

20H

Hpo20

Set Hpos to 20

V

Vpo

Vertical positioning

0

255

V

Vpo73

Read V position

W

Hsz

Horizontal width

0

255

W

Hsz128

Read H width

S

Vsz

Vertical size

0

255

157S

Vsz157

Set Vsize

h

Hpn

Horizontal panning

0

255

128h

Hpn128

Set H panning

v

Vpn

Vertical panning

0

255

v

Vpn102

Read V panning

w

Hzm

Horizontal zoom factor

0

255

100w

Hzm100

Set H zoom

s

Vzm

Vertical zoom factor

0

255

150s

Vzm150

Set V zoom

Output commands

* T

TSO

Output standard

0

63

T

TSO33

Read Output standard

F

FLK

Filter Flicker level

0

7

4F

FLK4

Set to level # 4

N

BLV

Black level

0

255

N

BLV128

Read Black level

R

REDLV

Red level

0

255

106R

REDLV106

Set Red level

G

GRELV

Green level

0

255

G

GRELV128

Read Green level

B

BLULV

Blue level

0

255

B

BLULV127

Read Blue level

Genlock controls

k

GLK

Genlock status

0

2

k

GLK0

Read Genlock status

I

SCPH

Sub carrier phase setting

0

1023

522I

SCPH522

Set SC Ph

i

HPHI

Horizontal Sync phase setting

0

255

138i

HPHI138

Set H Ph

Input status (Read only)

d

DHI

Horizontal period of input
signal

0

65535

d

DHI564

Read line frequency

l

GRT

Number of line per field

0

65535

l

GRT525

Read line per field

* t

TSY

Sync type

0

255

t

TSY113

Read Sync type

u

UNIT

Measures unity in kHz

0

65535

u

UNIT17734 Read unity of measures

Miscellaneous

* c

MISC

Miscellaneous controls

0

31

c

MISC0

Read controls

* b

BP

Front panel actions

0

31

8b

BP8

Set Freeze mode

?

DEV

device type

0

2

?

DEV1

Read device type

M

M_

"M" Firmware Version

0

65535

M

M_13316

Read "M" Version

L

L_

"L" Firmware Version

0

65535

L

L_18915

Read "L" Version

r

R_

"R" Firmware Version

0

65535

r

R_57427

Read "R" Version

* See Chapter 10-4 COMMANDS DESCRIPTION

10-3. ERROR RESPONSES

When the STUDIO SCAN receives from the host an invalid command or value, it returns an error response:
E10

invalid command (See : "Command" Column)

E13

invalid value (See "Value" Column)