beautypg.com

2 mechanical – AMETEK MX Series Rev: AY User Manual

Page 23

background image

User Manual – Rev AY

AMETEK Programmable Power

MX Series

23

2.1.7 Unit Protection

Input Over current:

In-line fast acting fuses. Check fuse rating in Service and Maintenance
section. Ratings will depend on AC input configuration settings.

Circuit breaker for LV supply.

Input Over voltage:

Automatic shutdown.

Input Over voltage
Transients:

Surge protection to withstand EN50082-1 (IEC 801-4, 5) levels.

Output Over current:

Adjustable level constant current mode with programmable set point.

Output Short Circuit:

Peak and RMS current limit.

Over temperature:

Automatic shutdown.

2.2 Mechanical

Parameter

Specification

Dimensions:
(for each MX chassis)

Height:

50.0”

1270 mm

Width:

28.75”

731 mm

Depth:

34.5”

876 mm

Unit Weight:
(for each MX chassis)

Net:

1150 lbs / 522 Kg approximately

Shipping:

1231 lbs / 560 Kg

approximately

Material:

Steel chassis with aluminum panels and covers.

Finish:

Light textured painted external surfaces.

Panels semi-gloss polyurethane color no. 26440 (medium gray)

Cooling:

Fan cooled with air intake on the front and exhaust to the rear.
Fans:

6 x 225CFM.

Air displacement

22 Cu Ft/sec. Max.

Internal Construction:

Modular sub assemblies.

Rear Panel
Connections:

(See section 3 for description of connections)

Cable entry and strain relieve for AC input wiring

Cable entry and strain relieve for output wiring

External sense terminal block (Remote voltage sense)

System interface (2x)

Clock and Lock BNC's (requires -LKM or -LKS options)

RS232, USB, GPIB, LAN (option)

Trigger In BNC

Trigger Out BNC

Function Strobe BNC

Output Status