Scroll to the RTCA/DO-160D entry using the up and down cursor keys. Press the ENTER key to
select the RTCA/DO 160D main menu. The screen will appear as shown in Figure 9-2.
Note: The user has to turn on the Output relay before starting a test.
Figure 9-2: DO160 Main Menu
9.3.1.5 AC TESTS
Note: Prior to test selection the standard and the group selection are required. Use the shuttle to
select the standard and the group if applicable.
9.3.1.5.1 Normal state test
Scroll to the NORMAL STATE AC entry using the up and down cursor keys. Press the ENTER
key to select the NORMAL STATE screens. The screen will appear as shown in Figure 9-3.
Figure 9-3: Normal State
The DO160 NORMAL 1 and NORMAL 2 screens have the following tests:
1
VOLT FREQ MIN
2
VOLT FREQ MAX
3
VOLT UNBALANCE
4
WAVEFORM DISTORTION
5
VOLT MODULATION
6
FREQ MODULATION
7
POWER INTERRUPT
8
VOLTAGE SURGE
9
FREQ TRANSIENT (group 1)
FREQ VARIATION (group 2 & 3)
The above tests can be selected by scrolling to the highlighted selection using the up and down
key and the ENTER key to start the selected test. For some of these tests, numeric data entry
may be required to define the test number or the modulation rate.
VOLT FREQ MIN
Standard/Group
RTCA
Group1
Group2
Group3
Voltage
1
100
104
104
104
3
101.5
105.5
105.5
105.5