4.5 Standard Measurements

Standard measurements are always available through the MEAS key on the front panel. These
measurements are spread across two to four screens to enhance readability. Switching between
these screens can be done by successively pressing the MEAS button on the front panel. This
will cause the screen to cycle through all available measurement screens.

4.5.1 Standard Controller Measurements

For MX Series power sources with the –1 or –3 standard controllers, the following two
measurement screens are available:

Mode

AC

DC

MEASUREMENTS 1

VOLTAGE

AC rms voltage

DC Voltage

CURRENT

AC rms current

DC Current

FREQUENCY

Frequency

n/a

POWER

Real power

power

MEASUREMENTS 2

VA POWER

Apparent power

power

PEAK CURR

Highest AC current

found

Highest DC current

found

POWER FACT

Power factor

n/a

CREST FACT

Crest factor

n/a