beautypg.com

AMETEK MX Series Rev: AY User Manual

Page 12

background image

User Manual – Rev AY

AMETEK Programmable Power

MX Series

12

1.3 Different Model Series

There are two versions of the MX Series product, Series I and Series II. This user manual covers both
MX model series with top level assembly part numbers 7003-400 (Series I) and 7003-422 (Series II).
The difference between the Series I and the Series II is the controller used. The Series II uses a
newer controller design but retains backward compatibility with the Series I products. The part number
is shown on the model / serial number tag on the back of the MX series. All Series II will have a
firmware revision of 4.0 or higher. The firmware revision is displayed briefly at power up on the LCD
display and can also be queried over the bus by using the *IDN? command.

Differences between the two model series are restricted to:

Reduced number of measurement calibration coefficients on Series II.

Increased measurement sampling rate on Series II.

Maximum DC offset range in AC+DC mode is 250Vdc on Series I, 220Vdc on Series II

Where relevant, differences are highlighted throughout the user manual.