2.3.8

4-20mA Current Source Programming of Output Current

SW1 Switch Settings

SW1-2 ON (1) = 4-20mA

10

4-20mA

11

12

13

1

2

25

14

23

Set up for 4-20 mA programming of the output current as follows:

1.

Set SW1-2, I PROG, to ON (1) for 4-20mA programming range.

2.

Connect the external programming current source to the ISOLATED ANALOG
PROGRAMMER connector, J4, with the source to Pin-10 and the return to Pin-13.

3.

Connect a jumper from Pin-13 to Pin-12 to connect the 4-20mA current sense resistors
to common.

4.

Connect a jumper from Pin 23 to Pin 11 to provide the negative 2.5VDC to zero out the
4mA signal generated by internal circuits.

5.

Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG PROGRAMMER
connector, J4, to Pin-2 to enable remote control.

6.

Program the other parameters to the desired limit values.

2-14

M51A Option