Isolated Analog Programmer Operation

2.3 Remote Programming Configuration

2.3.1

Voltage Source Programming of Output Voltage

SW1 Switch Settings

SW1-1 ON (1)= 0–5V
SW1-1 OFF (0)= 0–10V

2

9

12

13

1

25

14

Set up for voltage source programming of the output voltage as follows:

1.

Set SW1-1, V PROG, to ON (1) for 0-5VDC programming range.

2.

Set SW1-1, V PROG, to OFF (0) for 0-10VDC programming range.

3.

Connect the external programming voltage source to the ISOLATED ANALOG
PROGRAMMER connector, J4, with positive to Pin-9 and negative to Pin-12.

4.

Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG PROGRAMMER
connector, J4, to Pin-2 to enable remote control.

5.

Program the other parameters to the desired limit values.

M51A Option