DLM-E Series and DCS-E Series

Isolated Analog Programmer Operation

2.3.5 Resistance

Programming of Output Current

SW1 Switch Settings

SW1-2 ON (1) = 0–5K

2

10

12

13

1

25

22

14

Set up for resistance programming of the output current as follows:

1.

Set SW1-2, I PROG, to ON (1) for 0-5VDC programming range.

2.

Connect the external programming resistance, 0-5kΩ, to the ISOLATED ANALOG
PROGRAMMER connector, J4, from Pin-10 to Pin-12.

3.

Connect a jumper from Pin-22 to Pin-10 to connect the 1mA current source.

4.

Connect Pin-1, ANALOG-CONTROL, of the ISOLATED ANALOG PROGRAMMER
connector, J4, to Pin-2 to enable remote control.

5.

Program the other parameters to the desired limit values.

M51A Option