Connecting to a smartcontroller – Adept Smart Vision MX User Manual
Page 18
Chapter 2: Installation
Figure 2-4. DC Connector with Wires
Adept SmartVision MX
User-supplied
Power Supply
(24 VDC, 6 A)
User-supplied Shielded
Power Cable
Note: Use connector
supplied by Adept at
this end of cable
Optional
Fuse
Attach shield from user-supplied
cable to Adept SmartVision MX using
left wire slot in 24 VDC connector
Attach shield from user-
supplied cable to frame
ground on power supply
Circuit
protection
< 8 A
-
+
Frame Ground
+
-
Figure 2-5. Ground for 24 VDC Cable Connections
Connecting to a SmartController
The 24 VDC can be obtained from a SmartController if you are connecting the Adept SmartVi-
sion MX to one. The total current, used by both the Adept SmartController and the Adept
SmartVision MX, as well as any peripherals attached to them, must stay within the limits of
your 24 VDC power supply.
The 24 VDC power cable is user-supplied.
1. Connect a 24 VDC cable from XDC1 or XDC2 on the controller (whichever is not used)
to the 24 VDC connector on the Adept SmartVision MX industrial PC.
2. Follow the instructions in the previous section for connecting VDC to the Adept
SmartVision MX industrial PC.
Adept SmartVision MX User’s Guide, Rev. A