2.4 Connecting Power

Connect 24 VDC power to the input of the SmartVision MX.

External Power Supply

The SmartVision MX takes 4.2 A at 24 VDC. It requires filtered 24 VDC power.

NOTE: You must provide your own power supply. Make sure the power cables
and power supply conform to the specifications in the following table.

Customer-Supplied
Power Supply

24 VDC (-10%, +5%), 150 W (6 A)

Circuit Protection

Not more than 8 A (below the amper-
age rating of the cable used)

Power Cabling

1.5 - 1.85 mm

2

(16-14 AWG), full-

cover, braided shield cable, maximum
length 10 meters

Shield Termination

Braided shield connected to the left
wire slot of the VDC connector on the
power side of the Adept SmartVision
MX. On the other end of the cable, the
shield should be connected to the
power supply chassis.

CAUTION: Make sure you select a 24 VDC power supply that meets
the specifications in the preceding table. Using an underrated supply
can cause system problems and prevent your equipment from oper-
ating correctly. See the following table for recommended power sup-
plies.

Table 2-1. Recommended 24 VDC Power Supplies

Vendor Name

Model

Ratings

XP Power

JPM160PS24

24 VDC, 6.7 A, 160 W

Mean Well

SP-150-24

24 VDC, 6.3 A, 150 W