5. TECHNICAL SPECIFICATIONS
operation manual d06, chapter 6 - Technical Specifications - page 2 of 2
SYNC IN
WCLK
connector BNC, 75Ohm, coaxial
level
TTL-level
input format Wordclock
AES/EBU
connector BNC, 75 Ohm, coaxial
level 0,5 ... 5 Vpp
input format AES professional, AES consumer
VIDEO
connector BNC, 75 Ohm, coaxial
level 0...1 Vpp
input format Blackburst or PAL/NTSC composite video
WCLK OUT
WCLK
connector BNC, 10kOhm, coaxial
level TTL-level
output format Wordclock
REMOTE
serial remote interface
RS-232
connector 9 pin SUB-D female
serial remote interface
RS-422
connector 9 pin SUB-D female
serial remote interface
CAN (1.0)
GPI parallel remote
level opto coupler, 3 … 24V control voltage
connector 15 pin SUB-D female
Tally Out
level relais contact
connector 25 pin SUB-D female
power consumption
appr. 15 VA
dimensions 19“, 1 RU, 250 mm depth
weight appr. 5 kg
sync
in- / outputs
remote control
general