3. INSTALLATION
operation manual d06, chapter 3 - Installation - page 3 of 10
SYNC
SYNC IN
input for ext. sync signals :
AES 3 format, 75 Ohm, unbalanced
video sync (black burst), 75Ohm, unbalanced
word clock (TTL level), 75Ohm, unbalanced
Connector : BNC socket
WCLK OUT
output for word clock (system clock of d06)
(TTL level), 75Ohm
Connector : BNC socket
DIGITAL IN
AES/EBU standard
format
Connector :
XLR female
DIGITAL OUT
AES/EBU standard
format
Connector :
XLR male
ANALOG IN/OUT
Analog input
24bit A/D-converter
floating, balanced
Connector :
XLR female
Analog output :
24 bit D/A-converter
Floating, balanced
Connector :
XLR male
The analogue audio inputs are RFI filtered. Analog I/Os are balanced and
floating like transformer coupled devices. All the audio connectors are via rear
panel mounted connectors. Standard XLR connectors are used. These are
always wired to the AES standard:
pin 1
X
Shield
pin 2
L
Live
audio 0°
pin 3
R
Return audio 180°.
Balanced connections are preferred whenever the other equipment provides
balanced inputs/outputs. All line level connections should be wired with twin
shielded cable for low noise and reliability. The shields of the cable should be
connected at one end only. Input cable shielding therefore needs to be
derived from the signal source end as pin 1 is ground lifted for low frequencies
at the inputs.
If the equipment that drives the digital audio level processor d06 has
unbalanced outputs you must add a wire jumper to connect Pin 1 of the XLR
to Pin 3.
If the equipment connected to the d06 has unbalanced inputs only, we
recommend to use a balanced (i.e. 2 core shielded) cable where Pin 1 and
Pin 3 are connected in the XLR plug end away from the digital audio level
processor d06.
3.7.1
AUDIO
CONNECTIONS