3. INSTALLATION
operation manual d06, chapter 3 - Installation - page 7 of 10
Connector :
RJ 45 with status LEDs
8 pin panel jack
Pin assignment of the connector :
Pin
Signal name
Functions
1
TX +
Ethernet send
2
TX -
Ethernet send
3
RX +
Ethernet receive
4
5
6
RX -
Ethernet receive
7
8
9
Electrical specifications :
100Mbit/s auto negotiation port
Application remarks :
This port allows remote control of the d06 by TCP/IP over Ethernet (web
interface).
Setting up the network interface is described in chapter 4.
The LAN Controller of the d06 has a web server which offers a graphical user
interface (GUI). For proper operation you need IE7 or FireFox 2.0.
You simply must use the IP address of the do6 as an URL. (see chapter 5.1
for details).
d06 control block diagram :
3.7.5
LAN
(Ethernet)