4. LOCATION OF PARTS AND CONTROLS
4.2.
REAR PANEL
DIGITAL
INPUTS
SYNC IN
DIGITAL
OUTPUTS
BASIC
SETTINGS
SDI IN-/
OUTPUT
SERIAL
REMOTE
IN/OUT
GPI REMOTE
IN/OUT
fig. 2: rear panel b42
POWER INPUT
IEC mains input connector 230 V, 50 Hz (UK: 240 V, 50 Hz; JAPAN: 100 V,
60 Hz; USA: 127 V, 60 Hz) with integrated fuse
REMOTE
serial remote interface RS-422
connector:
9pin SUB-D, input - male, output - female
GPI
paralle remote interface
TALLY-out
TTL-level
connector:
9pin SUB-D, male
GPI-in
TTL-level
connector: 9pin SUB-D, female
SYNC
AES/EBU
input for ext. sync signal (AES 3 format, 75 Ohm, unbal)
connector: BNC socket
VIDEO
input for video sync signal (blackburst, 75 Ohm, unbal)
connector: BNC socket
SDI IN / OUT (only for SDI-Version!)
Input/output for serial digital video (ITU-R BT.601, SMPTE 272M-A)
with embedded audio
Format:
270 Mb/s, 525/625 line rate, 75 Ohm,
connector: BNC socket
DIGITAL IN
input for AES/EBU standard format
connector: XLR female panel jack
1- ground, 2-3 signal, balanced
connector: BNC socket 75 Ohm, unbalanced
DIGITAL OUT
output for AES/EBU standard format
connector: XLR male panel jack
1- ground, 2-3 signal, balanced , 4 Vpp
connector: BNC socket 75 Ohm, unbalanced, 0.5V pp