beautypg.com

Junger Audio b45 - Digital Audio Delay User Manual

Page 14

background image

3. INSTALLATION

3.6

SYNCHRONIZATION
OF
DIGITAL OUTPUT

The digital audio delay b45 has a digital signal output only. To
the problem-free combination of following digital devices, the
digital signal processing can be locked to an external clock
reference. The selection of the corresponding input is made in
the SYNC MODE menu. If the chosen sync input is connected
with the sync signal, this signal is used for synchronization
automatically. The digital output signal can be clocked with the
following clock frequencies:

CH 1/2

locks with the clock frequency of the input signal at

digital input CH 1/2 (AES/EBU, 48 kHz)

EXT SYNC locks with the clock frequency at the

external sync input (AES/EBU, 48 kHz)

VIDEO

locks with the clock at the Video sync input

(internal 48 kHz)

SDI VIDEO locks with the clock at the SDI input

(internal 48 kHz)


Both digital outputs CH 1/2 and CH 3/4 are locked with same
clock frequency.

Note: SDI sync is available only if SDI input is active!

page 3-2 Operation manual b45, chapter 3 -installation-