Junger Audio b45 - Digital Audio Delay User Manual
Page 22

4. LOCATION OF PARTS AND CONTROLS
Main
board
Tracking
Board
J1
SDI direct
J2- tracking control signal
B45
Download
switch
Use jumper J2 on the tracking board for selection of tracking
mode (tracking control signal input) (see also 2. ).
Auto Tracking
with
Video
with
TTL
J2
J2
All following settings are related to the SDI interface. The SDI interface can be fitted
only after removing the tracking module. That means if the box is equipped with SDI
interface no tracking functions are available anymore!
4.4
SELECTION OF
AUTO TRACKING
MODE
4.5
SELECTION OF
SDI SPLIT MODE
Main
board
SDI
Interface
J1
SDI Split
SW1&2- SDI group
selection and others
B4x
Download
switch
Units with SDI interface can be used in SDI split mode:
Audio in path
SDI input > AES output
Audio out path
SDI output > dsp processing > AES output
(see also 2.5)
page 4-4 Operation manual b45, chapter 4 -location of parts and controls-