beautypg.com

J*am – Junger Audio J*AM Application Manager User Manual

Page 8

background image

J*AM

5


Reset Plot:

will do what it says

– you may reset the

measurement and start it again.
This will be prompted by a pop up.





? :

a "Help" menu is not available yet.


The

"About … " selection shows the

Junger Audio contact data, the software
version of the J*AM and presence of a valid
license for the Loudness Logging Tools.










The upper area of the live plot display offers a lot of detailed information and some setups you can also
find in the Display Option menu:


Module:

device (single device) or c8k module name


Loudness Distribution:

shows the loudness distribution of the short term values. This allows easy
estimation of how the levelling process can manage the desired target
compared to the source loudness distribution.

Program:

[Program 2]

name of the program that is measured by the live plot

Config:

[2/0]

configuration of the audio channels

Channel:

[7

– 8]

audio channels of the device or module used for that

program

Loudness Control Mode:

[EBU R128]

display of the actual loudness control mode of the

processor. You must not be confused by the loudness

measurement methods.

Integrated Loudness gated: [-25.8 / -22.2]

loudness measurement - input vs. output using

ITU BS.1770-2 (gated)

LKFS Input/Output:

unit of measurement for the integrated loudness

LKFS Input/Output ungated: [-27.4 / -23.2]

loudness measurement

– input vs. output using

ITU BS.1770-1 (ungated)

Loudness Range:

[12.8 / 9.6]

LU Input/Output:

unit of measurement for loudness range


Integr. Time:

integration time of the EBU R128 program loudness

measurement