Ivie iFlex 2400 Series User Manual
Page 5

3
1. Description - Assigns a user-defined name to
the control. This helps the user to recognize
the control when making associations,
assigning level groups, defining logic, etc..
2. Port Definition - Logical ports are
associated with smart controls that have
internal id numbers, description names,
setup parameters, etc. Physical ports are
associated with controls that are hard-wired
to a specific port.
3. Output or LED - Determines whether the
control has an LED.
4. Switch - Determines whether the control has
a switch.
5. Switch Type - Identifies the switch type as
a toggle, static or door. Note - doors are
defined logically as switches in the system,
but have a unique icon and display method.
6. Level/Selector/Neither - Determines whether
the control has a level, selector or neither.
7. Pot/UP/Down/Bi-Pulse - Determines
whether the level is a pot, up-down switches,
or bi-pulse encoder.
8. Group - Assigns a group name to a level
9. Manage Groups - Allows the user to create
and manage group names.
10. Color - Sets the color of the currently named
group.
11. Range - Sets the range of a level.
12. Plus Off - Sets the level to off as level goes