Ivie iFlex 2400 Series User Manual
Page 28

26
Input and output modules, and controls are pre-programmed at the factory
with a type designator. This designator is used to identify the type of
module or control to be programmed, and is used to populate the list in the
upper-right corner of the hardware programmer dialog box.
As with associating mixers, the hardware programming dialog matches
physical modules and controls with logical modules and controls in the
software layout screen. Inputs, outputs, and controls have names in the
layout screen, and these names are accessed through the pulldown menu
below the list of found modules and controls.
When a physical module or control is selected from the list in the upper-
right corner, a picture of the module or control type appears below, with
a pull-down menu of modules or controls in the layout of that same type.
Selecting a name from the list to assign to the hardware is all that is
required to fully program the module or control.
When a module or control is programmed, the list of found hardware will
show the programmed name to the right of the hardware type.
RMPC Controls
The RMPC line of pc board adapters convert custom analog control panels
into smart controls over a single RS485 cable. Programming RMPC
controls is similar to the matching process described above, but individual
pots, led’s, and switches must be hardwired to the RMPC board.
When an RMPC control is selected in the list of found modules and
controls, a wiring diagram for that type of RMPC is shown in the lower