Ivie iFlex 2400 Series User Manual
Page 19

17
When connected, the bar beneath the graph will show the current level of
compression.
The limits for input values are as follows:
Limit Threshold - -30 to 20
Compression Threshold - -30 to 20
Ratio - 1 to 100
Attack and release time units are in milliseconds, and have no realistic
limits.
High Shelf / Cut
The high shelf / Cut processing block has input parameters for frequency,
gain, and filter type. Frequency and gain can be entered through the key-
board, and filter type through a pull down menu. These values can also be
input by dragging the shelf point with the mouse, and using the wing tool.
Use the cut checkbox in the lower-left corner of the dialoge to select cut
v.s. shelf filtering. As with other dialogs, the user can bypass the process-
ing block with the bypass check box.
The filter types available for this processing block are:
6dB LR
12dB Butterworth
12dB Bessel
12dB LR
18dB Butterworth
18dB Bessel
24dB Butterworth
24dB Bessel
24dB LR