Operation, Ilumicode, Ilumicode panel description – ILUMINARC Ilumiline™ 36 IP User Manual
Page 17: Menu map, Vw functions menu map

Operation
Ilumiline 36 IP Optic (RGB or VW) User Manual Rev. 6
13
4. Operation
When you scroll
through the
menu options,
you will see
many of them that do not
correspond with this menu
map. Skip them, as they
do not work with the VW
output products.
Ilumicode
The Ilumiline 36 IP Optic (RGB or VW) needs an external controller, the Ilumicode addresser,
to change its configuration.
Ilumicode Panel Description
Menu Map
The products in the Ilumiline 36 IP Optic Series have distinct menu maps based on the colors
they produce, whether RGB or VW. The Ilumicode includes the functions for both types of
products.
VW Functions Menu Map
(Ilumiline 36 IP Optic VW)
This menu map shows you which parameters of the Ilumicode controller correspond to
the Ilumiline 36 IP Optic VW product.
Main Level
Programming Levels
Description
DMX
001~512
N/A
Sets the DMX starting address
PERSON
VW
N/A
3-channel: SpectraWhite control
VW+D
4-channel: SpectraWhite control + dimmer
SOLID
1-channel: dimmer
DIMMER
OFF
N/A
Dimmer work in linear mode
DIM 1
Dimmer works in non-linear mode, from fast to
slow.
DIM 2
DIM 3
DIM 4
STATIC
COOL
0~255
Configures the static color and effect
WARM
Button
Function
Exits from the current menu or function
Enables the currently displayed menu or sets the
currently selected value into the selected function
Navigates upwards through the menu list and increases
the numeric value when in a function
Navigates downwards through the menu list and
decreases the numeric value when in a function
Turns the unit on. The unit will turn off automatically
after 30 seconds of inactivity.