Operation
6
Ilumiline 36 IP Optic (RGB or VW) User Manual Rev. 6
3. Installation
Always connect
the Ilumiline 36
IP Optic (RGB or
VW) to a protected circuit
with an appropriate
electrical ground to avoid
the risk of electrocution or
fire.
Never connect
the Ilumiline 36 IP
Optic (RGB or
VW) to a rheostat
(variable resistor) or
dimmer circuit, even if the
rheostat or dimmer
channel serves only as a
0 to 100% switch.
Make sure to
connect the
Ilumiline 36 IP
Optic (RGB or VW) to a
power line with the proper
voltage and frequency, as
per the specifications in
this manual or on the
product’s sticker.
The listed
current rating
indicates the
maximum current draw
during normal operation.
If you choose to
bury the power or
signal distribution
boxes, make sure that
they are IP67 rated or
greater.
AC Power
The Ilumiline 36 IP Optic (RGB or VW) has an auto-ranging power supply that can work with
an input voltage range of 100~240 VAC, 50/60 Hz.
Make sure that you are connecting this product to the proper voltage, as per the specifications in
this manual or on the product’s sticker.
Power Consumption
To determine the power requirements for the Ilumiline 36 IP Optic (RGB or VW), see
the label affixed to the side of the product. Alternatively, you may refer to the
specifications chart in the Technical Information chapter of this manual.
The listed current rating indicates the maximum current draw during normal operation.
AC Plug
The Ilumiline 36 IP Optic (RGB or VW) comes with a bare-ended power input cord
for hardwire installation. Use the table and the illustration below to wire a plug.
Connection
Wire (US)
Screw Color (US)
Wire (Europe)
IP67 Pin
AC Live
Black
Yellow or Brass
Brown
1
AC Neutral
White
Silver or Gray
Blue
2
AC Ground
Green/Yellow
Green
Green/Yellow
3
Power Wiring
You can connect the bare-ended IP67 rated AC power cable from the product to an
IP67 rated power connector or IP67 rated junction box.
If using junction boxes, make sure to use IP67 rated conduit for surface installations.