Controls, Reset, System – Dan Dugan Sound Design Dugan-MY16 User Manual
Page 36
Dugan-MY16 User Guide
36
Controls
The Master controls, located on the far right, include
reset, system, meters, OVERRIDE
,
PRESET
, and
MUTE
. A set of buttons appears for each active group.
Reset
Press the
reset
button to restore the Dugan-MY16 to factory default settings. This is
the same as pressing the rear panel
RESET
button. This sets
•
channel modes and presets to auto
•
override
buttons to inactive
•
weights to 0 dB
•
groups to a
•
bypass
buttons to inactive
•
channel names to defaults
•
meters mode to gain
System
When multiple Dugan units are linked, groups a, b, and c span linked units and operate
as independent automatic mixers.
It is possible to have multiple systems of linked units on your network. These units
will all appear in the Top Pane. The Dugan-MY16 allows 16 systems in a network.
In the rare instance that requires multiple systems:
1. Select the first unit to include in the system by clicking it in the Top Pane.
2. Click the system button and select a unique number for that system.
3. Repeat for each unit in that physically linked system, making sure to use the same
number for each unit in the system.
4. Repeat steps 1–3 for each system.