Meters, Weight – Dan Dugan Sound Design Dugan-MY16 User Manual
Page 31
Dugan-MY16 User Guide
The Dugan Control Panel
31
Meters
The meters have three display modes.
Table 3-1 Meter modes
The default meter display is
auto mix gain
. This is the most useful choice during normal
operation; the input and output meters are only used when setting or checking levels.
Click on the Master
meters
button to toggle through the three meter display modes.
Weight
The
weight
controls set the side-chain levels for each channel into the control system.
This establishes the relative sensitivity of the automatic mix for the channels in use.
They do not change the mix levels. When the
weight
controls are balanced, each mic has
an equal opportunity to take over the system: when one person talks into one mic,
he/she gets all the
auto mix gain
and the others get turned down.
Figure 3-8 Weight controls
The
weight
controls should be used to balance the channel
auto mix gain
indicators
when no one is talking. If a board preamp trimmer is turned down, that channel’s
weight
control can be turned up to re-balance the automixing, and vice-versa.
Weights can be changed by dragging the sliders or by entering dB values in the win-
dows below the sliders. Ctrl-click the
weight
slider to reset its value to 0.
Touch and hold the
weight slider to reset its value to 0.
Meter Displays
Meter Color
auto mix gain
action of the Dugan Speech System
green
input
input level
yellow
output
output level
blue
iPad