4. Press and hold the rear panel NETWORK RESET button for 3 seconds.

This resets the following network parameters to their factory default value.

*xx = last two digits of serial number, unless 00, then use 100

5. Click Refresh List.

6. Click on the first unit in the list so it is highlighted.

If Unit Reachable is YES, you are ready to use the Dugan Control Panel with that
unit. If you have additional Dugan units to connect, select the next unit in the list
and repeat Step 3. If you are finished with installation, proceed to Chapter 4: Du-
gan Control Panel
.

If Unit Reachable is NO, proceed to the next step.

7. Select the Use DHCP parameter.

8. Click Send New Params to Unit.

9. Highlight the unit in the list pane again.

If Unit Reachable is YES, this unit is ready to use with the Dugan Control Panel. If
you have additional Dugan units to connect, select the next unit in the list and
repeat Step 3. If you are finished with installation, proceed to Chapter 4: Dugan
Control Panel
.

If Unit Reachable is NO, proceed to the next step.

10.Copy This Computer’s IP Address to the IP Address field, and increase the value in

the last (fourth) group by one.

For example, if This Computer’s IP Address is 192.168.1.101, set IP Address to
192.168.1.102.

11.Click Send New Params to Unit.

12.Highlight the unit in the list pane again.

If Unit Reachable is YES, this unit is ready to use with the Dugan Control Panel. If
you have additional Dugan units to connect, select the next unit in the list and
repeat Step 3. If you are finished with installation, proceed to Chapter 4: Dugan
Control Panel
.

If Unit Reachable is NO, see Using the Internally Stored Dugan Control Panel on page 19.

IP Address

192.168.1.xx*

Netmask

255.255.255.0

Gateway

192.168.1.254

DHCP

off