5.4. Programming

The pressure of the

button and holding it down through ca 3

seconds causes the entry to the programming matrix. If the entry is pro-
tected by a password, then the safety code symbol SEC is displayed
alternately with the set value 0. The write of the correct code causes the
entry in the matrix, the write of an incorrect code causes the display of
the ErCod symbol. The matrix of transitions to the programming mode
is presented on the fig. 8. The choice of the level is made by means of
the

button, however the entry and moving through the para-

meters of the chosen level is carried out by means of the

and

buttons. Parameter symbols are displayed alternately with their

current values. In order to change the value of the chosen parameter,
one must use the

button. For resignation from change, one must

use the

button. In order to exit from the chosen level, one must

chose the ----- symbol and press the

button. To exit from the

programming matrix, one must press the

button during ca 1

second. Then, the symbol End appears for ca 3 seconds and the meter
transits to the display of the measured value. In case of leaving the
meter in the parameter programming mode, the automatic abandon of
the programming mode follows (parameter, and next the menu) after 30
seconds and the meter transits to display the measured value.

5.4.1. Value Change Way of the Selected Parameter
In order to increase the value of the selected parameter, one must
press the

button. A single pressure of the button, causes the

increase of the value of 1. The increase of value when displaying the
digit 9 causes the set of 0 on this digit. The change of the digit follows
after pressing the

button. In order to accept the set parameter,

one must hold down the

button. Then, the write of the parameter

follows and the display of its symbol, alternately with the new value. The
pressure of the

button during the change of the parameter value

will cause the resignation of the write.