Current
The maximum supply current required by the SWM24 is shown in the chart below with different power supply voltage
inputs. You will note in the chart that the Drive+Motor does not draw as much current as the motor itself. That’s because
the SWM24 uses switching amplifiers, converting a high voltage and low current into lower voltage and higher current.
The more the power supply voltage exceeds the motor voltage, the less current you’ll need from the power supply.
Also note that the current draw is significantly different at higher speeds depending on the torque load to the motor.
Estimating your current needs may require a good analysis of the load the motor will encounter.
SWM24-3 12V Power Supply Current
Motor Current: 6A/phase
0
0.5
1
1.5
2
2.5
0
10
20
30
40
50
Speed(RPS)
To
rq
ue
(N
.m
)
0.00
0.50
1.00
1.50
2.00
2.50
3.00
3.50
4.00
4.50
Am
ps
Torque
Supply Current
Supply Current
No Load
SWM24-3 24V Power Supply Current
0
0.5
1
1.5
2
2.5
0
10
20
30
40
50
Speed(RPS)
To
rq
ue
(N
.m
)
0.00
0.50
1.00
1.50
2.00
2.50
3.00
3.50
4.00
4.50
Am
ps
Torque
Supply Current
Supply Current
No Load
Motor Current: 6A/phase
9
SWM24 Hardware Manual
920-0068B