Led error codes, 34 swm24 hardware manual – Applied Motion SWM24IP-3EE User Manual
Page 34

LED Error Codes
Status LED SWM
The SWM24 drive+motor includes a red/green LED to indicate status. When the motor is enabled, the LED flashes green
slowly. When the green LED is solid, the motor is disabled.
Errors are indicated by combinations of red and green “flashes” as follows:
Code
Error
solid green
no alarm, motor disabled
flashing green no alarm, motor enabled
fast green
Q program running
1 red, 1 green motor disabled after a stall condition occurred
1 red, 2 green move attempted while drive disabled
2 red, 1 green ccw limit
2 red, 2 green cw limit
3 red, 1 green drive overheating
3 red, 2 green internal voltage out of range
3 red, 3 green blank Q segment
4 red, 1 green power supply overvoltage
4 red, 2 green power supply undervoltage
4 red, 3 green flash memory backup error
5 red, 1 green over current / short circuit
5 red, 2 green I/O occupied
6 red, 1 green open motor winding
6 red, 2 green bad encoder signal
7 red, 1 green serial communication error
7 red, 2 green flash memory error
34
SWM24 Hardware Manual
920-0068B
10/31/2013